Please use this identifier to cite or link to this item: http://hdl.handle.net/11434/2075
Title: Do evoked potentials matter? Pre-pathologic signal change and clinical outcomes with expandable cages in lateral lumbar interbody fusion surgery.
Epworth Authors: Malham, Gregory
Munday, Nigel
Other Authors: Hamer, Ryan
Biddau, Dean
Keywords: Expandable Interbody Fusion
IONM
LLIF
Lateral Lumbar Interbody Fusion
Multimodal Electrophysiologic Monitoring
Degenerative Disk Disease
Foraminal Stenosis
Spinal Deformity
Expandable Cages
Neurosciences Clinical Institute, Epworth HealthCare, Victoria, Australia
Issue Date: Jan-2022
Publisher: Elsevier
Citation: J Clin Neurosci . 2022 Feb 24;98:248-253
Abstract: Minimally Invasive Lateral Lumbar Interbody Fusion (MIS LLIF) is a reliable technique for treatment of degenerative disk disease, foraminal stenosis and spinal deformity. The retroperitoneal transpsoas approach risks lumbar plexus injury that may result in anterior thigh pain, sensory loss and weakness. A prospective study of 64 consecutive patients undergoing MIS LLIF with expandable cages (23 standalone, 41 integrated with lateral plate) using multimodal electrophysiological monitoring was performed. We measured sequential retraction times, complications, patient reported outcome scores and electrophysiologic findings with a minimum 12-month follow-up. Incidence of evoked potential and electromyographic signal change was moderate, and rarely resulted in post-operative neurologic deficit. Evoked potential signal changes were frequently resolved by the un-breaking of the surgical table or repositioning of the retractor. Average retraction times were 24 (15-41) minutes for standalone cages and 30 (15-41) minutes for integrated cages. At follow-up, the vast majority (97%) of patients reported significant clinical improvement post-operatively with only 2 patients reporting postoperative neurologic symptoms and subsequent recovery at 12-months. The present study shows that evoked potentials combined with electromyography is a more sensitive measure of pre-pathologic lumbar plexopathy in LLIF compared to electromyography alone, especially at L3/4 and L4/5 levels. Based on our findings, there is limited clinical indication for routine neural monitoring at rostral lumbar levels. The routine inclusion of multimodal electrophysiological monitoring in lateral transpsoas surgery is recommended to minimise the risk of neural injury by enabling optimal patient and retractor positioning and continued surveillance throughout the procedure.
URI: http://hdl.handle.net/11434/2075
DOI: 10.1016/j.jocn.2022.02.023
PubMed URL: https://pubmed.ncbi.nlm.nih.gov/35220141/
ISSN: 0967-5868
Journal Title: Journal of Clinical Neuroscience
Type: Journal Article
Affiliated Organisations: Faculty of Medicine & Health, University of Sydney, Sydney, NSW, Australia.
Swinburne Institute of Technology, Melbourne, VIC, Australia.
Type of Clinical Study or Trial: Prospective Study
Appears in Collections:Neurosciences

Files in This Item:
There are no files associated with this item.


Items in Epworth are protected by copyright, with all rights reserved, unless otherwise indicated.